What is a tenement, and what is a traditional building?
In Scots law, a tenement is a building, or part of one, with at least two flats that are, or are designed to be, separately owned and are divided from each other horizontally. The Scottish House Condition Survey 2024 describes pre-1919 tenement flats as the type common in Edinburgh and Glasgow, and puts them at 7% of Scotland’s homes. A Historic Environment Scotland (HES) blog post describes traditional Scottish tenements as three or four storeys high, with thick solid stone outer walls and steep pitched slated roofs.
A traditional building, in the Scottish Government’s guidance on converting them, is a building of a type constructed before or around 1919, using the construction techniques of that time and permeable components that let moisture leave the fabric. The guidance says most have mass masonry walls plastered on the inside, often on timber lath, timber floors and roof structures, and pitched roofs normally covered in slate.
Over 2022 to 2024, 74% of Glasgow households and 62% of Edinburgh households lived in flats, the two highest shares of any Scottish council, according to the survey’s local authority tables. The national survey also says older dwellings built with solid stone walls are typically less effective at stopping heat passing through them.
Does a thermal camera read sandstone well?
Yes. A thermal camera measures the infrared a surface gives off, and to turn that into a temperature it needs the surface’s emissivity, which FLIR calls the most important setting to get right. HES says many building materials, stone, plaster and wood among them, have a high emissivity of around 0.9 to 0.95, so a camera set to that value should give accurate results on most of them. FLIR’s published table lists rough sandstone at 0.935, and FLIR says the figures in that table are recommendations only.
Other surfaces on the building can mislead. Polished metal has a low emissivity, so the camera mostly sees what it reflects. Glass gives sharp, mirror-like reflections, often of the cold sky, and the camera cannot see through a window into the room behind it.
Why does a thick stone wall need longer heating?
Heat from inside has to work its way through the wall before the surfaces settle, and on solid masonry that is slow. For the clearest results HES advises heating a building to at least 10 °C above the outside air. It adds that the heating has to run long enough for the surfaces to warm to some depth, that on a solid masonry wall this could take a long time, and that it is usual to ask for the heating to stay on for 24 hours, or at least overnight, before a survey.
A RICS Built Environment Journal article of 28 October 2021 asks for more: a constant 20 to 22 °C inside for at least 72 hours before the inspection. It is a member’s article by a practising thermographer, not RICS guidance.
More heat is not the answer either. HES warns against raising the temperature too far in a historic interior: a painted timber ceiling, for example, can be damaged if the air is too hot or too dry, and gas heaters add a lot of water vapour. Its advice is to accept the heating that can reasonably be achieved.
From outside, the sun is the other problem. A wall in direct sunlight can keep that heat for several hours, so HES says heat loss imaging is done in darkness, ideally in the early morning before sunrise. High wind, it says, chills the surface and blows the contrast away. It also says better quality data usually come from inside the building, where conditions are better controlled and the temperature contrast is normally higher. Our guide on when to book a thermal imaging survey in Scotland covers the season and the weather.
What can a thermal image show on a solid stone wall?
Patterns of surface temperature, which then need explaining. HES warns that thermal images can easily be misinterpreted, and that the cause of an anomaly has to be confirmed on site. The table sets out patterns HES describes, what each can mean and what else to know.
| What the image shows | What it can mean | What else to know |
|---|
| A colder area inside, or a warmer one outside, at one part of the wall | A thermal bridge, where heat flows out faster than through the wall around it | HES says knowledge of how the wall is built is usually needed to find the cause |
| A cooler patch on the wall surface | A wet surface, cooled by evaporation | Water held deeper in a wall can show warmer as it cools, and in cold, humid air damp may not show at all. The image cannot tell rain getting in from a leaking pipe or condensation, so damp is confirmed with other checks, such as moisture sensors |
| Streaky or wispy cold marks | Air leaking in and chilling the surface | The camera sees the chilling, not the moving air, and draught chilling can be mistaken for damp |
| Cold room corners | Usually nothing | HES says corners are normally colder and this is not a defect |
| Warm patches on a sunlit harled or rendered wall, after the sun has left it | Harling or render that has come away from the wall | HES says it is unlikely to show anything on walls the sun has not heated, so it is a different survey from a heat loss survey before sunrise |
Two limits matter on these buildings. The camera reads the surface: HES says it cannot see below it, and shows what lies beneath only where that changes the surface temperature. And the problem has to be there at the time of the survey: a wall that is dry when it is imaged will not show damp.
Can a thermal survey give the U-value of a stone wall?
Not a reliable one. HES says U-values can be worked out from thermal images, but they are much less reliable than measurements from heat flux sensors, and those worked out from outside images are particularly unreliable. It says any such figure should be taken as only generally indicative of relative heat loss, and that reliable heat flow data measured in place need monitoring over at least two weeks. What a survey gives you is a picture of where a wall loses more heat than the wall around it.
What this guide cannot tell you
What is wrong with a particular wall, or what to do about it. A thermal image points to where to look, and other checks on site find the cause. Whether and how to repair or insulate a traditional building is for the owner and their own building professional to decide, and this guide gives no advice on it. It describes these buildings in general: yours may differ.
How Kanna Spatial does it
Kanna Spatial surveys buildings inside and out with a handheld thermal camera, and from the air by drone where a flight is possible. Carried out with reference to BS EN ISO 6781-1:2023. Our own survey method asks for at least a 10 °C difference between inside and outside, with the heating on for at least 12 hours beforehand where possible, and we survey 1 to 2 hours after sunset or before sunrise, with no rain and wind under 5 m/s. If the conditions are not right on the night, we move the date. You get thermal and visible images side by side and a written report of findings and anomalies.
Our public thermal case studies include the Glasgow Museums Resource Centre, a drone thermographic survey of the roofs and elevations, and Bridgnorth Police Station in Shropshire, surveyed inside and by drone on the same visit. Neither is a tenement. Send us the address and what you want to find out.