What is a thermal bridge?
In short
A thermal bridge is a part of a building where heat escapes faster than through the fabric around it, often at a junction or around an opening.
Also called: Cold bridge
The Scottish building standards handbook explains why junctions lose more heat. Heat flows in two or three directions there, not straight through. At corners and eaves the outside surface is larger than the inside one, lintels and other steel or concrete parts conduct heat well, and gaps where materials meet can let air move. Repeating bridges, such as the studs in a timber frame wall, are already counted in the wall’s calculated U-value.
In a thermal image, Historic Environment Scotland says, a thermal bridge shows as an unusually cold area from inside and as a warm patch from outside. Room corners and stud lines normally read colder and are not defects in themselves, so a knowledge of how the building is put together is usually needed to say what causes a pattern.
Heat lost along a junction is described by its psi-value, in watts per metre per kelvin. U-Value.com, our sister product, explains psi-values and thermal bridging in more detail.
Why it matters on a project
A thermal bridge adds to heat loss, and the cold inside surface can fall below the dew point, where condensation and mould can form. For homes in Scotland the handbook’s guidance is a surface temperature factor of at least 0.75.
How Kanna Spatial uses it
Kanna Spatial’s thermal imaging surveys show likely thermal bridges as anomalies in a written report of findings, with thermal and visible images side by side. See our thermal imaging surveys.
- 1Handheld camera: rooms, reveals and junctions
- 2Drone camera: roofs and high elevations
- 3Missing or slumped insulation
- 4Thermal bridge at a lintel or floor edge
- 5Air leakage around a window
- 6Cold surface at risk of condensation
- 7Shiny metal and glass: mostly reflections
Related terms
- Psi-value Thermal imaging and building performance
-
A psi-value, or linear thermal transmittance, is the extra heat lost along each metre of a junction between building elements for each degree of temperature difference, heat that the U-values of the walls, floors and roofs do not count, in watts per metre per kelvin (W/mK).
- Surface condensation and the temperature factor Thermal imaging and building performance
-
Surface condensation is water vapour condensing on a cold inside surface, where it supports mould; the surface temperature factor, fRsi, compares how warm that surface stays with the indoor and outdoor air, and Scottish guidance for dwellings is at least 0.75.
- Dew point Thermal imaging and building performance
-
The dew point is the temperature at which air becomes saturated with water vapour and water starts to condense, so condensation forms on surfaces colder than it; for indoor air at 20 °C and 50% relative humidity it is about 9.3 °C.
- U-value (thermal transmittance) Thermal imaging and building performance
-
A U-value, or thermal transmittance, is how much heat passes through one square metre of a wall, roof or floor for each degree Celsius of difference between the two sides, in W/m²K; the lower it is, the better the element insulates.
- Emissivity Thermal imaging and building performance
-
Emissivity is a measure, from 0 to 1, of how much heat radiation a surface gives off compared with a perfect emitter at the same temperature.