Skip to content

Glossary

What is emissivity?

In short

Emissivity is a measure, from 0 to 1, of how much heat radiation a surface gives off compared with a perfect emitter at the same temperature.

Last reviewed .

A thermal camera measures infrared radiation, not temperature directly. To turn what it sees into a temperature it needs an emissivity setting, and one setting applies to the whole image. FLIR calls emissivity the most important setting to get right. In its example, the same saved image reads a maximum of 65.0 °C at an emissivity of 0.95 and 77.3 °C at 0.7.

Historic Environment Scotland notes that most building materials, such as stone, plaster and wood, are around 0.9 to 0.95 and read well. Polished metals that have not oxidised are often below 0.3, so the camera mostly sees reflections of their surroundings and temperature readings on them are likely to be wrong. FLIR’s published table, which it says should be used with caution, gives 0.93 for red common brick and 0.04 to 0.06 for polished aluminium. Glass is a separate case. Historic Environment Scotland explains that infrared at these wavelengths does not pass through ordinary glass, so the camera reads the glass surface, and that surface gives sharp, mirror-like reflections, often of the cold sky.

Why it matters on a project

A cold patch on a wall and a cold reflection in a window can look alike in a thermal image. Knowing which surfaces have low emissivity tells you which readings to trust and which to check another way. On a radiometric image the emissivity can be corrected after the survey and the temperatures recalculated.

How Kanna Spatial uses it

Kanna Spatial treats spot readings on shiny metal and glass as unreliable, for the reason above. See our thermal imaging surveys.

Sources

3
  1. Short Guide 10: Thermal Imaging in the Historic EnvironmentHistoric Environment Scotland. Read
  2. Reference documentation: Thermography (T810442)FLIR Systems. Read
  3. Emissivity tables (T505002)FLIR Systems. Read
Radiometric image Thermal imaging and building performance

A radiometric image is a thermal image saved with its measurement data, so temperatures can be read and recalculated from it after the survey.

Reflected apparent temperature Thermal imaging and building performance

Reflected apparent temperature is the apparent temperature of the surroundings that a surface reflects into a thermal camera; the camera uses it to correct for reflections, which matters most on low-emissivity surfaces, and it is not the air temperature.

Also called: Tref, Reflected temperature

Apparent temperature Thermal imaging and building performance

Apparent temperature is a thermal camera's uncorrected reading of a surface, which includes all the radiation reaching the camera whatever its source, reflections included; the temperatures in a thermal image are apparent temperatures.

Black body Thermal imaging and building performance

A black body is an ideal surface that absorbs all the radiation falling on it and gives off the most heat radiation possible for its temperature; its emissivity is 1, and real surfaces are measured against it.

Also called: Blackbody

Thermal bridge Thermal imaging and building performance

A thermal bridge is a part of a building where heat escapes faster than through the fabric around it, often at a junction or around an opening.

Also called: Cold bridge

  • Service

    Thermal imaging surveys

    A thermal imaging survey uses an infrared camera to show the surface temperatures of a building, so heat loss, missing insulation, thermal bridges and the cold surfaces caused by air leakage can be seen.

Send the address and what you need. We reply with a fixed price, usually the same working day.